Vista de página 0
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and manual updates. Contact Bunn-O-Matic
Corporation at 1-800-286-6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.
35879.0001 01/08 ©2005 Bunn-O-Matic Corporation www.bunn.com
INSTALLATION & OPERATING MANUAL
SINGLE TF
DBC
W/SMART FUNNEL
®
S/N SNG0033000 & UP
Vista de página 0
1 2 3 4 5 6 ... 53 54

Resumo do Conteúdo

Página 1 - SINGLE TF

BUNN-O-MATIC CORPORATIONPOST OFFICE BOX 3227SPRINGFIELD, ILLINOIS 62708-3227PHONE: (217) 529-6601 FAX: (217) 529-6644To ensure you have the latest

Página 2 - 35879.1 011108

Page 10CLEANING1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic

Página 3 - TABLE OF CONTENTS

Page 11GLOSSARYAD CARD: An assembly consisting of computer chips and an instruction label. Used for loading advertising messages into the brewer.BREW

Página 4 - MAIN ON/OFF

Page 12PROGRAMMING Using the menu-driven display on the front of the brewer, the operator has the ability to alter or modify various brewing paramete

Página 5 - USER NOTICES (cont.)

Page 13MAIN SCREEN This screen will be shown when the brewer is ready for use. The screen displays the water temperature in the tank. When the water

Página 6

Page 14PROGRAMMING THE BREWER (cont.)PROGRAM FUNCTIONS - LEVEL 2 There are three methods of programming the various brewing parameters of the S

Página 7 - CE REQUIREMENTS

Page 15PROGRAMMING THE BREWER (cont.)LEVEL IPress upper right hidden switch for approximately 2 seconds, until the following screen appears.LEVEL II

Página 8 - OPERATING CONTROLSf

Page 16Continues to (E)(D)ENABLE ADS? NO DONE YES SET TEMP: 200°F (-) DONE (+) SET READY 195°F (-) DONE (+)0 REFILL 1

Página 9 - COFFEE BREWING

Page 17CALIBRATE FLOW? NO YESBREW COUNTERS? NO YESFUNNEL DETECT NO DONE YESSERVICE TOOLS NO YESSEL BREWER TYPE? NO YES(E)FINI

Página 10 - CLEANING

Page 18UNITSMETRIC DONE ENGCHANGING UNITSWILL!! ERASE!!ALL PREVIOUSLYSTORED RECIPESAND ALL SETUPINFO WIL BE LOST!ARE YOU SURE?YES NOSELECT

Página 11 - GLOSSARY

Page 19Procedure for Setting the Recipe:NOTE: Before beginning setup, place a server beneath the brew funnel.1. Insert the funnel into the grinder an

Página 12 - PROGRAMMING

Page 235879.1 011108BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTYBunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:1) All equipm

Página 13 - NO DONE YES

Page 20SET NEW RECIPES (cont.)8. Using (-) and (+), set the amount of brew water, in ounces, to be dispensed for that particular batch size. 9. When

Página 14 - 35879.1 071405

Page 21PROGRAMMING THE BREWER (cont.)POSITION CARD UNDER THELEFT SIDE SENSOR COIL(COFFEE NAME)SHOW QUIT SAVECARD CONTAINSRECIPE FORREADY TO BREWWATE

Página 15

Page 22SET NEW RECIPE:If not using a Smart Funnel (with a sensor coil) and/or a G9-2T DBC or MHG Grinder, the brewer will function as a standard Bunn

Página 16

Page 23REVIEW RECIPES/MODIFY RECIPES/SET UP NO NAME COFFEE NAMES: This function has three parts. It allows the operator to view the brew settings

Página 17 - PROGRAM FLOW DIAGRAM (Cont.)

Page 24BREW OZ (SETTING OR ADJUSTING BREW VOL-UMES) This function allows adjustment of the brew vol-umes for each batch. The indicator signifie

Página 18 - METRIC DONE ENG

Page 25P2444PROGRAMMING THE BREWER (cont.)% BYPASS This function allows adjustment of the amount of water that bypasses the grounds. The number signi

Página 19

Page 26PROGRAMMING THE BREWER (cont.)SET PULSE BREW: This function allows the operator to program the brewer to "pulse” the sprayhead flow on and

Página 20

Page 27SET PULSE BREW (cont.)PROGRAMMING THE BREWER (cont.)EXIT TONEXT FUNCTIONSCREENPRESSDONEYESDONEYESSCREEN DISPLAYEDBREW OZ: XX.XX3 BATCHES DONE?%

Página 21

Page 28PROGRAMMING THE BREWER (cont.)P35075 SEC. DELAYSET PULSE BREW?NO YES3 BATCHES DONE?NO YES3 BATCHES DONE

Página 22 - NEXT FUNCTION

Page 29PROGRAMMING THE BREWER (cont.)SET PULSE BREW - ENTER TIMESNOTE: The procedure to enter the PULSE BREW function must be performed prior

Página 23

Page 3TABLE OF CONTENTSUser Notices ...

Página 24

Page 30PROGRAMMING THE BREWER (cont.)SET PULSE BREW?NO YESENTER TIMES?NO YESEASY PULSE SETUPNO

Página 25

Page 31PROGRAMMING THE BREWER (cont.)DRIP TIME (now displayed on "non" funnel lock units as well) This function allows the setting o

Página 26

Page 32PROGRAMMING THE BREWER (cont.)ENABLE ADS? This function allows the operator to choose whether or not to display the advertising message that w

Página 27

Page 33PROGRAMMING THE BREWER (cont.)Procedure to set the sensitivity threshold of the refill circuit:NOTE: Make sure the water in the tank is t

Página 28 - ENTER TIMES

Page 34PROGRAMMING THE BREWER (cont.)Procedure to adjust the flow rate setting:1. Press and hold the upper right hidden switch until the display reads

Página 29

Page 35PROGRAMMING THE BREWER (cont.)Procedures to calibrate the bypass flow rate:1. Place a container, accurately graduated in ounces, and with a min

Página 30

Page 36PROGRAMMING THE BREWER (cont.)BREW COUNTERS This function allows the operator to track the num-ber of brew cycles completed. There is one rese

Página 31

Page 37PROGRAMMING THE BREWER (cont.)SERVICE TOOLS This function allows the testing of individual com-ponents and the ability to check switches for p

Página 32 - (-) DONE (+)

Page 38to TEST SWITCHES.7. Pressing NO in this screen will advance to the next function. Press YES in the TEST SWITCHES screen to test the sw

Página 33

Page 39PROGRAMMING THE BREWER (cont.)FACTORY DEFAULTS This function allows the operator to erase all of the previously entered recipes and ad message

Página 34 - BYPAS OZ/M: XXX

Page 4USER NOTICESThe notices on this brewer should be kept in good condition. Replace unreadable or damaged labels.35879.1 01110800656.000000831.000

Página 35

Page 40TROUBLESHOOTINGA troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the

Página 36 - NO DONE YES

Page 41TROUBLESHOOTING (cont.)Screen Displayed Possible Cause Troubleshooting Procedures1. Water temperature in the tank does not meet the

Página 37

Page 42TROUBLESHOOTING (cont.)Troubleshooting ProceduresPossible CauseScreen Displayed 1. ON/OFF switch was pressed after the brew cycle was start

Página 38

Page 43TROUBLESHOOTING (cont.)Troubleshooting ProceduresPossible CauseScreen Displayed 1. Water shut off to brewer2. Inlet Solenoid Valve failure3

Página 39

Page 44Equipment will not operate.Brew cycle will not start.Automatic refill will not operate or display shows FILL TIME TOO LONG1. No power o

Página 40 - TROUBLESHOOTING

Page 45Troubleshooting ProcedureTROUBLESHOOTING (cont.)ProblemPossible CauseCheck the sensitivity setting. Refer to the Refill function. If the l

Página 41 - TROUBLESHOOTING (cont.)

Page 46TROUBLESHOOTING (cont.)ProblemPossible CauseTroubleshooting ProceduresCheck the sensitivity setting. Refer to the Refill function. If the

Página 42

Page 47TROUBLESHOOTING (cont.) ProblemPossible CauseTroubleshooting ProceduresRemove power from the brewer. Connect a voltmeter across one of t

Página 43

Page 48TROUBLESHOOTING (cont.)ProblemPossible CauseTroubleshooting ProceduresPerform the previous procedure for testing triacs. If the voltage

Página 44

Page 49TROUBLESHOOTING (cont.)Problem Possible CauseTroubleshooting ProceduresAdjust the brew volume as required to achieve the recommended volume fo

Página 45

Page 535879.1 110507ELECTRICAL HOOK-UPWARNING – If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service perso

Página 46

Page 50TROUBLESHOOTING (cont.)ProblemPossible Cause Troubleshooting ProceduresConsider adjusting bypass percent-age, preinfusion, or pulse brew. C

Página 47

Page 5135726.0000B 02/07 © 2003 Bunn-O-Matic Corporation120/208 OR 120/240 VOLT A.C.3 WIRE + GNDSINGLE PHASESCHEMATIC WIRING DIAGRAMSINGLE TF DBC

Página 48

Page 5236883.0000A 05/04 © 2004 Bunn-O-Matic Corporation230 OR 200VOLT A.C.SINGLE PHASESCHEMATIC WIRING DIAGRAMSINGLE TF DBCFUNNEL LOCKSOLSOLSOLS

Página 49

Page 5336883.0002A 11/04 © 2004 Bunn-O-Matic Corporation120 VOLT A.C.2 WIRE SINGLE PHASE60HZSCHEMATIC WIRING DIAGRAMSINGLE TF DBCFUNNEL LOCKSOLSO

Página 50

Page 5436883.0001B 02/07 © 2004 Bunn-O-Matic Corporation200,208 or 240 VOLT A.C.2 WIRE + GNDSINGLE PHASE 50/60HZSCHEMATIC WIRING DIAGRAMSINGLE T

Página 51 - SINGLE TF DBC

Page 6L1, L2, L3, are the 3 phasesV1 = Phase to phase voltage, between any 2 phases.V2 = Phase to neutral voltage, L1 to neutral must be 120V. SYSTEMV

Página 52

Page 7PLUMBING REQUIREMENTSThis brewer must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a

Página 53

Page 8 (a) MAIN ON/OFF SWITCH This switch, located under the brewer behind the front leg, turns power on and off to all components in the brewer.(b)

Página 54

Page 9INITIAL SETUPCAUTION – The brewer must be disconnected from the power source throughout the initial setup, except when specified in the instructi